The selected type controls the structured parameter fields shown in the form. No type has required detail fields. Most types share a common core — amplitude or concentration, duration, profile, repetitions, and whether the stimulus was closed loop — so the descriptions below concentrate on what distinguishes each one. The order follows the Type dropdown.
Electrical and Magnetic Stimulation
Stimulation with electric currents or magnetic fields, through implanted electrodes, transcranially or by an applied field.
- Deep brain stimulation (DBS): Electrical stimulation delivered through an implanted electrode to a defined deep target. Use this rather than Electrical stimulation when the defining feature is the chronic deep-target implant. Structured fields: amplitude, duration, profile, duty cycle, repetitions, injection polarity, and closed loop.
- Electrical stimulation: General electrical stimulation through an electrode, including intracortical and peripheral stimulation. This is the default electrical choice when no more specific type applies. Structured fields: as for DBS.
- Electromagnetic field stimulation: Exposure to an applied electromagnetic field rather than current delivered through a contacting electrode. Structured fields: as for DBS.
- Transcranial electrical stimulation: Current applied through scalp or skull electrodes without penetrating the tissue, covering direct, alternating, and random noise variants. Record which variant was used in the profile and notes. Structured fields: as for DBS.
- Transcranial magnetic stimulation (TMS): Non-contact induction of currents in tissue using a magnetic coil. Structured fields: as for DBS.
Optical, Thermal and Ultrasound Stimulation
Stimulation with light, temperature change or ultrasound, including optogenetic stimulation.
- Optogenetic stimulation: Light delivered to drive or suppress genetically targeted cells. Record the wavelength, since it is what distinguishes excitation from inhibition for most opsins. Structured fields: power, wavelength, profile, duration, duty cycle, repetitions, and closed loop.
- Thermal perturbation: Deliberate heating or cooling of tissue, such as focal cooling used to silence a region. Structured fields: amplitude, duration, profile, duty cycle, repetitions, and closed loop.
- Ultrasound stimulation: Focused ultrasound used to modulate activity, as distinct from ultrasound used to image, which is a Data acquisition. Structured fields: acoustic pressure, acoustic intensity, duration, duty cycle, profile, repetitions, injection polarity, and closed loop.
Chemical and Pharmacological Perturbations
Delivery of drugs or other agents by injection, inhalation, superfusion, microperfusion or other liquid application.
- Liquid perturbation: A change of the fluid around the preparation or exposed tissue whose effect comes from the solution itself, such as an osmotic challenge, ionic substitution or a bath-medium switch. Local delivery through a probe is Microperfusion; a drug in the bath is Pharmacological superfusion. Structured fields: concentration, volume, profile, repetitions, flow rate, and closed loop.
- Microperfusion: Local delivery or exchange of a solution inside tissue through an implanted probe or line at low flow, as in open-flow microperfusion or reverse microdialysis. Use it when the agent reaches a small target volume; bath-wide changes are Liquid perturbation or Pharmacological superfusion. Structured fields: as for Liquid perturbation.
- Pharmacological inhalation: An agent delivered through the respiratory route during the session. Structured fields: concentration, flow rate, profile, volume, repetitions, and closed loop.
- Pharmacological injection: An agent injected during the session to perturb the system under study. A drug given as clinical care, such as analgesia or anesthesia, is a Procedure instead. Structured fields: as for Liquid perturbation.
- Pharmacological superfusion: An agent applied by bathing the preparation in solution, the usual route for slice and other ex-vivo work. Structured fields: as for Liquid perturbation.
Sensory Stimulation
Presentation of auditory, visual, tactile, odor or combined sensory stimuli to the subject.
- Auditory stimulation: A presented sound, such as a tone, click, or noise burst. Recording sound is a Data acquisition, not a Manipulation. Structured fields: amplitude, duration, frequency, modulation frequency, profile, duty cycle, repetitions, and closed loop.
- Multisensory stimulation: Two or more modalities presented as one designed stimulus. Use this when the timing between modalities is part of the experiment; record separate entries when the stimuli are independent. Structured fields: modalities, temporal relationship, duration, repetitions, and closed loop.
- Odor stimulation: A presented olfactory stimulus, usually delivered by an olfactometer. Structured fields: concentration, flow rate, repetitions, and inhalation phase.
- Tactile stimulation: A mechanical stimulus applied to the body surface, such as whisker deflection or a von Frey filament. Structured fields: contact type, stimulation site, force, duration, profile, repetitions, and closed loop.
- Visual stimulation: A presented visual stimulus, such as a grating, flash, or natural scene. Structured fields: stimulus types, stimulus position, duration, repetitions, and closed loop.